Model 250 ENT
air handling unit with Enthalpy exchanger
The Airfi Model 250 ENT air handling unit ensures healthy, fresh indoor air year-round. Airfi Enthalpy recovers both heat and moisture ensuring optimal indoor comfort, balanced humidity and reduced energy costs. The unit is suitable for ventilation in large single-family houses, apartment buildings, healthcare and educational facilities, and sports halls.
- Equipped with an ERV (energy recovery ventilation) core. Additional heating via an electric post-heater is used only when necessary.
- The AFPS™ defrost system ensures continuous ventilation and optimizes the unit’s performance in all conditions.
- Highest quality of filtration. Supply: ePM1 55% + ISO Coarse 90 %, exhaust: M5 ISO ePM10 60%.
- Compatible with various building automation systems.
- Delivered with attached and adjustable stand.
Apartment size max: 450 m²
Supply air: electric 893 / water 875 m³/h
Extract air: 954 m³/h (electric, water)
Models
| Product code | Infromation | ||
|---|---|---|---|
| Model 250 ENT (R) Electric | 110250011 | Enthalpy Exchanger | White |
| Model 250 ENT (L) Electric | 11025021 | Enthalpy Exchanger | White |
| Model 250 ENT (R) Water | 11250012 | Enthalpy Exchanger | White |
| Model 250 ENT (L) Water | 11250022 | Enthalpy Exchanger | White |
Contact Our Sales Team
Contact us- Dimensions (width x hight x depth)998 x 1475 x 650
- Weight168 kg
- Duct outlets4 x 250
- Kitchen bypassNo
- Condensate fitting128 mm from the front edge
- Condensate water trayTilted
- Max. extract air flow rate (100 Pa)Electric 954 m³/h, Water 954 m³/h
- Max. supply air flow rate (100 Pa)Electric, 893 m³/h, Water 875 m³/h
- Specific energy consumption (SEC) in a cold climateA+
- Specific energy consumption (SEC) in an average climateA
- Extract air heat recovery annual efficiency classA+/A (kitchen bypass in use)
- Air handling unit’s specific electrical power class at rated air flowA
- Electricity230 V,16 A, max.3500 W: Plug
- Water230V,50Hz,16A, max.1100W
- Post heater2380 W (electric / water)
- Heat recovery typeEnthalpy Exchanger
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat.
Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
Why choose Airfi Enthalpy Air Handling Unit
Air handling units with energy recovery
ventilation technology (ERV)
Model 53 mini ENT
Maximum apartment size: 160 m²
Supply air: 324 m³/h
Extract air: 342 m³/h
Model 60 ENT
Apartment size max. 200 m²
Supply air: 356 m³/h
Extract air: 385 m³/h
Model 130 ENT
Apartment size max: 250 m²
Supply air: 450 m³/h
Extract air: 511 m³/h
Model 150 ENT
Apartment size max.: 300 m²
Supply air: 572 m³/h
Extract air: 648 m³/h
Model 250 ENT
Apartment max size: 450 m²
Supply air: electric 893 / water 875 m³/h
Extract air: 954 m³/h (electric, water)
Model 350 ENT
Apartment size max: 550 m²
Supply air: electric 1256 / water 1242 m³/h